Files
chimera-gfx-Public/docs/runtime/phase-0.9d-independent-recovery-analysis.md
Chimera GFX release export a6037502d7
phase0-ci / build-and-audit (push) Successful in 2m14s
Publish Chimera GFX source
2026-09-03 03:27:14 +02:00

3.7 KiB

Phase 0.9D independent recovery analysis

Date: 2026-07-18 Status: UNPROVEN

elfldr

Question Source-bound answer
Write mechanism none in audited source
Executor original external exploit/rudimentary loader could launch an ELF, but its source is absent
Works if elfldr is broken bootstrap independence is described, not demonstrated: PARTIAL
Works if Manager is broken bootstrap path does not name Manager: PARTIAL
Works after reboot UNPROVEN
Works without autoload manual host send is described: PARTIAL
Works without defective listener port 9020 is described as distinct from elfldr port 9021: PARTIAL
Exact restore target selectable no live target mapping or write contract
Write then verify absent
Old file remains intact no restore transaction exists
Power-loss behavior UNPROVEN; no atomic restoration contract
Second route none source-bound

Top-level required classification: PARTIAL. Detailed restore classifications: UNPROVEN and ABSENT; no INDEPENDENT_RECOVERY_CANDIDATE is established.

Payload Manager

Question Source-bound answer
Write mechanism full Manager upload/install routes write files, but using a Manager to restore that same Manager is self-dependent and is not authorized
Executor elfldr can launch a Manager ELF sent from a host, according to README/deploy source
Works if elfldr is broken no; described manual Manager route depends on elfldr: CROSS_DEPENDENT
Works if Manager is broken a separately supplied candidate could be launched through elfldr, but persistent restoration is absent: PARTIAL
Works after reboot original exploit and elfldr repeatability are UNPROVEN
Works without autoload manual send is described: PARTIAL
Works without normal Manager listener host-to-elfldr launch is structurally separate: PARTIAL
Exact restore target selectable no current live mapping
Write then verify absent
Old file remains intact upload/install paths are not an audited self-recovery transaction
Power-loss behavior existing writes/renames are not proven safe for the current live Manager object
Second route absent

Top-level required classification: PARTIAL. Detailed classifications: CROSS_DEPENDENT, SELF_DEPENDENT, and POWER_LOSS_UNSAFE for the available shapes. None is recovery proof.

Failure matrix

Failed component Still source-plausible Not proven / unavailable
elfldr original port-9020 exploit bootstrap, if the absent external chain remains usable current exploit availability, persistent rewrite, exact target, verification, power-loss recovery
Payload Manager elfldr remains capable of accepting and launching a separately supplied ELF in source Manager live path, durable replacement, independent verification, recovery when elfldr also fails

The current byte-exact Payload Manager backup remains HARD_BLOCKER_FOR_INSTALLATION. Lack of independent recovery remains HARD_BLOCKER_FOR_EVERY_DEVICE_WRITE.

Side-by-side feasibility

elfldr socksrv.c:477-507 terminates an already running elfldr.elf service before creating another one. Payload Manager main.c:81-103 terminates another pldmgr.elf instance during startup. Both therefore have process/listener overlap and global-state risks.

The controlled Manager source uses a separate profile/port but is not installed or runtime-proven. Any candidate would require transfer and execution, a source-bound non-live path, collision review, a timeout/cleanup contract, and independent recovery. None exists here.

Classification: BLOCKED / RECOVERY_UNPROVEN. This is not staging, installation, or execution approval.